Major’s Lab RNA Engineering Lab Français

MC-Flashfold

Fast RNA secondary structure prediction and exploration of alternative structure sets, with non-canonical base pairs

Predict secondary structures

Version

v37 (January 2018) scores structures differently from v34: it adds the energy of the base pair closing each hairpin, so energies are lower and the best structure can differ from v34, from the user manual and from the 2016 chapter. Known problems: for sequences longer than about 200 nucleotides it may return far fewer structures than requested, or none; duplex modes may return nothing or run until the time limit. v34 is recommended.

1. Sequence

2. Structures to compute

Return

structures

kcal/mol of the best energy

% of the best energy

An energy window that would give more than 1,000 structures is reduced to the best 1,000, with a notice.

3. Folding options

4. Structural constraints (option)

Masks restrict the search. One symbol per nucleotide: . unpaired, x unconstrained, ( ) paired together; the second mask also accepts per-nucleotide symbols such as | paired or - not canonically paired. All symbols

5. Output masks (option)

Output masks do not change the search: each structure that matches one is labelled with its name. Up to 10, the length of the sequence.

6. Analyses (option)

Structures are connected by

move(s)

In duplex mode: the first sequence is the target region (up to 200 nt); give an energy window (up to 10 kcal/mol or 20 %); masks cover target + 2-nucleotide linker + second sequence. How duplex modes work

Reset Help